← MSHA accidents

FALL OF ROOF OR BACK

220110420032 · 02/06/2011 · Consol of Kentucky Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol of Kentucky Inc
Mine
4605978

Narrative

An unintentional roof occurred at break 104 in the #4 entry (belt). Size of fall was estimated to be 12'L x 7'W x 3'-31/2'Thick. No injuries, ventilation was not interrupted, belt line was caught. Fall will be cleaned up. The roof had been supported with 6' fully grouted resin bolts

Source

Authoritative
MSHA Open Government Data