An unintentional roof occurred at break 104 in the #4 entry (belt). Size of fall was estimated to be 12'L x 7'W x 3'-31/2'Thick. No injuries, ventilation was not interrupted, belt line was caught. Fall will be cleaned up. The roof had been supported with 6' fully grouted resin bolts