FALL OF ROOF OR BACK

220110800001 · 03/18/2011 · ICG Hazard, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
International Coal Group Inc (ICG)
Operator
ICG Hazard, LLC
Mine
1518991

Narrative

A non-injury un-intentional roof fall occurred (outby) on 1 North Main (return) in #2 entry between cross-cut 16 and 17. The dimensions are approximately 40 feet long, 20 feet wide and 6 feet thick. Rod material is laminated shale. The area was initially supported with 60 inch fully grouted resin rods.