← MSHA accidents
ELECTRICAL
220112340054
· 08/17/2011 · S & G Excavating, Inc.
Details
Degree of injury
DAYS AWAY FROM WORK ONLY
Classification
ELECTRICAL
Accident type
Flash burns (electric)
Occupation
Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer
Activity
Electrical maintenance
Injury source
ELECTRICAL APPARATUS,NEC
Nature of injury
ELECT.ARC BURN-NOT CONTAC
Body part
MULTIPLE PARTS (MORE THAN ONE MAJOR)
Days lost
1
Mine experience
17 years
Operator
Controller (parent)
Kenneth E Steiner Jr
Operator
S & G Excavating, Inc.
Mine
1202196
Narrative
Employee was replacing a fuse in the jaw disconnect box. After throwing the knife in the box, the employee used a fuse puller to remove the bad fuse. When replacing the fuse, the employee got the fuse holder into live electricity and got flashed.
Source
Authoritative
MSHA Open Government Data
Machine
JSON-LD
·
Markdown