A non-injury unintentional roof fall occurred at the mentioned mine approximately 1000 feet outby the 002 active section. The fall occurred in a neutral entry (#4) in an old roadway intersection on #5 Main. The fall was app. 7 to 8 feet thick, 26 feet wide and 25 feet long. Laminated shale gave way which was supported with 60 inch fully grouted rods.