← MSHA accidents

HOISTING

220171800010 · 06/25/2017 · Teck Washington Incorporated

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Teck Resources Limited
Operator
Teck Washington Incorporated
Mine
4500366

Narrative

On June 25th, the hoist went down around 9:00pm. The electrician on shift was not able to diagnose the problem so the hoist remained out of service for the remainder of the shift. The day shift electricians found that the hoist drive had tripped on over-voltage. They adjusted settings to reduce the secondary voltage and brought the hoist back on line.