← MSHA accidents

FALL OF ROOF OR BACK

220173050008 · 10/23/2017 · Consol Pennsylvania Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Pennsylvania Coal Company LLC
Mine
3607230

Narrative

An unplanned roof fall occurred in the 6L section in the #2 entry just out by 33 x-cut. The fall measured 15ft long by 6ft high by 10ft wide. The opinion formed during the investigation was that the fall was caused by adverse geological condition, in the form of a cutter running up the left bolt line.

Source

Authoritative
MSHA Open Government Data
Machine