← MSHA accidents

HOISTING

220202720005 · 09/24/2020 · Sunrise Coal, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Hallador Energy Company
Operator
Sunrise Coal, LLC
Mine
1202394

Narrative

During an inspection of the Emergency hoist it was discovered that the brake pad for the drum had pulled through the rivets and caused the pad to break in two. This was the only braking system for the drum as there is no secondary system. The hoist was immediately taken out of service and repairs started.

Source

Authoritative
MSHA Open Government Data
Machine