An unintentional roof fall occurred in the G2 Longwall section 2-3 crosscut at 39 wall Spad# 107+10. The fall was approximately 16' wide x 50' long x height unknown. The immediate roof consisted of laminated shale type material. Adverse geological conditions contributed to the failure. The fall was just at the longwall face at the time the fall occurred.