ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS
Miles at failure
74,105
Speed
70 mph
Severity
Deaths
0
Injured
0
Fire
Yes
Crash
No
Police report
No
Medical attention
No
Vehicle towed
No
Narrative
FUSE PANEL LOCATED ON TOP OF THE BATTERY MELTED IN THE AREA OF THE FUSE FOR THE RADIATOR COOLING FANS. THIS FURTHER DAMAGED THE FUSES FOR THE BRAKE SYSTEM AND THE ABS SYSTEM. THIS CAUSED POWER TO THE ABS SYSTEM TO BE LOST. THE DEALER DIAGNOSED THIS PROBLEM AS SHORTED COOLING FANS. HOWEVER, THE WIRING TO THE MOTORS AND THE FAN CONTROL UNIT WERE NOT AFFECTED. THERE WAS ALSO THE DISTINCT SMELL OF AN ELECTRICAL FIRE AND MELTED PLASTIC UNDER THE HOOD. THE FUSE PANEL HAS WHITE DEPOSITS UNDER ITS COVER ABOVE THE AREA THAT MELTED. I ASKED THE DEALER TO GIVE ME THE PARTS AFTER THE SERVICE. THE FAN MOTORS APPEAR TO OPERATE CORRECTLY WHEN CONNECTED TO A 12V POWER SUPPLY. THIS IS A POOR DESIGN THAT SUBJECTS THE FUSE TERMINALS TO CORROSIVE FUMES FROM THE BATTERY. THE INSERT MOLDED TERMINALS THEN BECOME CORRODED WITH HIGH ENOUGH RESISTANCE TO HEAT UP AND CAUSE THE FUSE PANEL TO MELT AND OR CATCH FIRE. I'M GLAD THAT THE PANEL WAS CONSTRUCTED OF A FLAME RETARDANT PLASTIC OR IT WOULD HAVE CERTAINLY BURNED MUCH MORE THAN IT DID. I AM ONLY TOO HAPPY TO FURNISH PICTURES IF YOU WOULD PREFER TO SEE THE DAMAGE. *NM