← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2015010041 · 1/3/2015 · Insteel Wire Products, Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Contact with objects and equipment, unspecified
Source
Extruding, injecting, forming, molding machinery, n.e.c.

Employer

Name
Insteel Wire Products, Inc.
Location
500 Klemp Road, DAYTON, TEXAS, 77535
NAICS
331222
Jurisdiction
1

Narrative

Employees use a draw machine to extrude wire. The employee bypassed the guard or disabled it to remove soap build-up on the wire coming from the die. The employee amputated the middle, ring, and pinky fingers on the right hand and the first digit of the index finger. Employee was hospitalized and released. The injury occurred on 1/3/15 at approximately 6:00 p.m.

Source

Authoritative
OSHA Severe Injury Reports
Machine