← OSHA severe injury reports

Other respiratory system symptoms-toxic, noxious, or allergenic effect

1 hospitalization · 2015020470 · 2/16/2015 · Ohio Valley Electric Corp.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Other respiratory system symptoms-toxic, noxious, or allergenic effect

Cause

Event
Inhalation of harmful substance-single episode
Source
Welding or soldering fumes, unspecified or n.e.c.

Employer

Name
Ohio Valley Electric Corp.
Location
5758 SR 7 North, CHESHIRE, OHIO, 45620
NAICS
221118
Jurisdiction
1

Narrative

An employee was arc welding on a boiler feed pump shaft that was made of 410 stainless steel. The employee was wearing a respirator designed for Hexavalent Chromium. The employee went to the hospital and was admitted for respiratory issues after finishing his shift.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown