← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2015041708 · 4/2/2015 · EnviroCore

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Arm(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Entangled in other object or equipment
Source
Drilling machines, drilling augers
Secondary source
Bars, rods, reinforcing bar (rebar)

Employer

Name
EnviroCore
Location
State Hwy 361 Midway, GREGORY, TEXAS, 78359
NAICS
238910
Jurisdiction
1

Narrative

An employee was attempting to connect a drill stem to a drill rod inside a bore hole. He was straightening the rod in the hole with his right hand and was using his other hand to run the controls. The cable was still connected at this time. He lowered the drill rod and used his hand to connect the slipper or hoisting cable from the drill rod in the hole. The cable and the drill rod started to spin around, pulling in and causing an amputation to his right hand and arm.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown