An employee removed a worn out sprocket from a Brehm Tube loader machine. The sprocket was repaired and placed back into the machine. The machine was energized and failed to automatically feed. The employee opened the machine while the machine was energized to try to engage the machine by pushing a chain with his left index finger. His finger was caught in the machine resulting in an amputation.