← OSHA severe injury reports

Amputations

1 amputation · 2015053098 · 5/21/2015 · GATOR STAMPING INTERNATIONAL, INC.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Milling machines
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
GATOR STAMPING INTERNATIONAL, INC.
Location
6610 33RD STREET EAST, SARASOTA, FLORIDA, 34243
NAICS
332116
Jurisdiction
1

Narrative

On May 21, 2015, at approximately 3:00 p.m., an employee was running the milling machine when his glove got caught in the milling cutter, amputating his right index finger.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown