← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2015053163 · 5/26/2015 · RIMCO PLASTIC CORPORATION

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, n.e.c.
Source
Extruding, injecting, forming, molding machinery, unspecified

Employer

Name
RIMCO PLASTIC CORPORATION
Location
316 COLONIAL DRIVE, HORSEHEADS, NEW YORK, 14845
NAICS
326199
Jurisdiction
1

Narrative

An employee was setting up the in-line vacuum forming machine line. The guard was off at the time of the incident and the interlock held down with a clamp. At the trim press stage, the employee came in contact with the steel rule die and amputated the index and middle fingers on the right hand.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown