← OSHA severe injury reports

Electrocutions, electric shocks

1 hospitalization · 2015063473 · 6/7/2015 · Loram Maintenance of Way, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Electrocutions, electric shocks

Cause

Event
Direct exposure to electricity, greater than 220 volts
Source
Fans, blowers-wall, floor, ceiling, ventilation

Employer

Name
Loram Maintenance of Way, Inc.
Location
Milepost 22, MAGNOLIA, TEXAS, 77354
NAICS
488210
Jurisdiction
1

Narrative

An employee was shocked by 480 volts when his left arm made contact with an energized blower/vacuum unit while removing water from under the blower. He was hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine