← OSHA severe injury reports

Second degree electrical burns

1 hospitalization · 2015086146 · 8/26/2015 · EAST BAY ELECTRIC, LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Multiple body parts, n.e.c.
Nature of injury
Second degree electrical burns

Cause

Event
Direct exposure to electricity, greater than 220 volts
Source
Power lines, transformers, convertors

Employer

Name
EAST BAY ELECTRIC, LLC
Location
13013 Willow Beach Rd, NORTH LITTLE ROCK, ARKANSAS, 72117
NAICS
238210
Jurisdiction
1

Narrative

An employee was working on a power line from a bucket truck moving wire lines from an old pole to set a new pole when the old cross arm braces broke and live electric wires fell on his right shoulder/arm. As a result of the two phased electrical contact flash, the employee suffered a second degree burn on the right shoulder and right side of his body and was hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine