← OSHA severe injury reports

Fractures and dislocations

1 hospitalization · 2015107623 · 10/13/2015 · Power Specialist Associates, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Upper and lower limb(s)
Nature of injury
Fractures and dislocations

Cause

Event
Other fall to lower level 21 to 25 feet
Source
Boilers

Employer

Name
Power Specialist Associates, Inc.
Location
Route 201, FAIRFIELD, MAINE, 04937
NAICS
811310
Jurisdiction
1

Narrative

An employee was wire brushing the interior of the #1 recovery boiler's forced draft fan duct. He lost his footing, the fan blades moved, and he fell into the duct. He fell approximately 25 feet to the 10th level of the boiler. He suffered a compound fracture of the right leg and dislocated the right shoulder and elbow.

Source

Authoritative
OSHA Severe Injury Reports