← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2016032090 · 3/9/2016 · RX SYSTEMS, INC

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Presses-printing

Employer

Name
RX SYSTEMS, INC
Location
121 Point West Blvd, SAINT CHARLES, MISSOURI, 63301
NAICS
424210
Jurisdiction
1

Narrative

An employee was loading paper into a printing press when the press did not move the paper along as designed. The employee jogged the machine and turned it off and then on, attempting to get the paper to move along. The employee's left index finger was caught in the machine, amputating the first digit of the finger.