← OSHA severe injury reports

Fractures

1 hospitalization · 2016042894 · 4/6/2016 · Enkei America, Inc.-Jacksonville

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Hand(s), unspecified
Nature of injury
Fractures

Cause

Event
Struck by object falling from vehicle or machinery-other than vehicle part
Source
Casting machinery

Employer

Name
Enkei America, Inc.-Jacksonville
Location
1401 WHEELS RD., JACKSONVILLE, FLORIDA, 32218
NAICS
331524
Jurisdiction
1

Narrative

An employee was running the casting machine when he noticed that the charge bucketful of ingots had come off of the elevator. When he attempted to pick up the ingots that had fallen onto the floor, the carrier arms (part of the chain lift elevator device) that held the charge bucket in place came down and struck his right hand, breaking it. He was hospitalized.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown