← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2016053792 · 5/4/2016 · Plastics Color Corporation

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Extruding machinery
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
Plastics Color Corporation
Location
14201 Paxton Avenue, CALUMET CITY, ILLINOIS, 60409
NAICS
325991
Jurisdiction
1

Narrative

On May 4, 2016, at approximately 2:30 pm, an employee noticed that the (powders) raw materials were not going down easily through the mixing chamber (approximately 165 cubic inches) of an extrusion machine fitted with a rotating shaft "rotor" with a maximum speed of 100/500 rpm's. He attempted to clear out the material from the mixing chamber with a putty knife at different speeds (controlled/adjusted by the employee himself) beginning at 460 rpm, then down to 120 rpm, and then up to 130 rpm when his gloved hand (cloth) holding the putty knife was pulled in the mixing chamber. The knife was thrown out and when he pulled his hand out his right thumb and three other fingers on his right hand were amputated.

Source

Authoritative
OSHA Severe Injury Reports
Machine