← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2016065646 · 6/23/2016 · Williams Form Engineering Corp.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Compressed or pinched by shifting objects or equipment
Source
Band saws

Employer

Name
Williams Form Engineering Corp.
Location
251 Rooney Road, GOLDEN, COLORADO, 80401
NAICS
332312
Jurisdiction
1

Narrative

An employee's finger was amputated when it got caught in a chain vice used to clamp stock for a band saw.