← OSHA severe injury reports

Fractures

1 hospitalization · 2016065720 · 6/27/2016 · ALDRIDGE ELECTRIC, INC.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Lower leg(s)
Nature of injury
Fractures

Cause

Event
Struck by discharged object or substance
Source
Machine, tool, and electric parts, n.e.c.
Secondary source
Handtools-powered, n.e.c.

Employer

Name
ALDRIDGE ELECTRIC, INC.
Location
Westbound I-90 at Mile Marker 59.5, HOFFMAN ESTATES, ILLINOIS, 60010
NAICS
238210
Jurisdiction
1

Narrative

On or about June 27, 2016, at 1:30 p.m., an employee was proofing an underground 1.25" polyduct when a blowing gun blew out of the line due to built-up back pressure. The employee had been standing to the side of the polyduct to be out of the line of fire. When the blow gun came out of the duct, the employee stepped over to pick up the gun to turn the air off and the blow dart then came out of the duct, striking him on the right shin. He was hospitalized and required surgery for a broken right tibia.

Source

Authoritative
OSHA Severe Injury Reports
Machine