← OSHA severe injury reports

Heat (thermal) burns, unspecified

1 hospitalization · 2016076269 · 7/12/2016 · Michael Facchiano Contracting, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Multiple body parts, n.e.c.
Nature of injury
Heat (thermal) burns, unspecified

Cause

Event
Ignition of vapors, gases, or liquids
Source
Cleaning and polishing agents, n.e.c.

Employer

Name
Michael Facchiano Contracting, Inc.
Location
801 McNeilly Road, PITTSBURGH, PENNSYLVANIA, 15226
NAICS
237310
Jurisdiction
1

Narrative

An employee was heating up a track frame pin with a torch. While the employee was removing the track frame pin, a hot bolt or part of the frame pin punctured an adjacent aerosol can of brake cleaner and the contents ignited into a ball of fame, causing thermal burns to the employee's lower left and right arms and face.