← OSHA severe injury reports

Fractures

1 hospitalization · 20161110287 · 11/1/2016 · Core-Mark International, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Foot (feet), unspecified
Nature of injury
Fractures

Cause

Event
Part of occupant s body caught between vehicle and other object in nonroadway transport incident
Source
Forklift, order picker, platform truck-powered
Secondary source
Racks-garment and other

Employer

Name
Core-Mark International, Inc.
Location
19500 Bulverde Road Suite #230, SAN ANTONIO, TEXAS, 78259
NAICS
424940
Jurisdiction
1

Narrative

An employee was driving a forklift toward a conveyor when he noticed an error light at the tote scanner. He traveled on the lift toward the tote scanning area to manually scan the tote in and clear the error. He attempted but was unable to slow the machine using the plugging method or the dead-man switch. He then attempted to exit the machine. In that process, he struck the racking and his left foot became wedged between the rack and the forklift. He suffered a broken left foot and deep abrasions.