← OSHA severe injury reports

Avulsions, enucleations

1 hospitalization · 2017010647 · 1/20/2017 · ESCO Corporation

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Avulsions, enucleations

Cause

Event
Compressed or pinched by shifting objects or equipment
Source
Forging machinery

Employer

Name
ESCO Corporation
Location
9098 East Side Drive Extension, NEWTON, MISSISSIPPI, 39345
NAICS
331513
Jurisdiction
1

Narrative

The wiring for an argon oxygen decarburization (AOD) motor caught fire and the AOD had to be operated manually. An employee attempted to insert a crank handle into the AOD crank. As the employee was manually tilting the AOD, it moved beyond the center of gravity and the crank handle started spinning rapidly. When the employee tried to grab the crank handle, his right middle finger was caught in the chain and sprocket, de-gloving the fingertip. The chain and sprocket was unguarded at the time of the incident.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown