← OSHA severe injury reports

Heat (thermal) burns, unspecified

2 hospitalizations · 2017010742 · 1/24/2017 · Emory University

Severity

Hospitalized
2
Amputation
0
Loss of eye
0
Body part
Multiple body parts, n.e.c.
Nature of injury
Heat (thermal) burns, unspecified

Cause

Event
Ignition of vapors, gases, or liquids
Source
Solvents, degreasers, n.e.c.

Employer

Name
Emory University
Location
1762 Clifton Road, ATLANTA, GEORGIA, 30322
NAICS
611310
Jurisdiction
1

Narrative

A graduate assistant teacher was preparing to run a column chromatograph7 purification wearing a flame retardant lab coat and safety glasses, as well as gloves, long pants and closed toed shoes. A second graduate assistant teacher was sitting at his desk in the same lab at the time. The first teacher struck the bottom of a 4L glass bottle of hexanes on the edge of the bench, while attempting to put the bottle down. The bottom of the bottle sheared off on contact with the bench and the contents spilled onto the ground. Some of the hexane spilled onto the teacher's lab coat, long pants (left leg) and shoe (left foot). After an initial assessment of the spill, the teacher collected absorbent towels and paper towels to begin to contain and clean up the spill. He was assisted by the second teacher who heard the breakage while sitting at his desk. Shortly after the teachers began to contain the spill, it ignited explosively causing a flash fire. Both teachers were burned and admitted to the hospital.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown