← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2017054400 · 5/15/2017 · Worthington Industries Engineered Cabs, Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Compressed or pinched by shifting objects or equipment
Source
Hooks, shackles, magnets, clamshells

Employer

Name
Worthington Industries Engineered Cabs, Inc.
Location
315 Airport Drive, WATERTOWN, SOUTH DAKOTA, 57201
NAICS
333120
Jurisdiction
1

Narrative

An employee flipped an LBX roof with a ceramic cam magnet attached to a hoist. The employee moved the magnet release handle, which operated a roller cam to release the magnet, then grabbed the opposite side to pull the magnet away. The magnet release handle switched back, engaging the magnet, which pinched and amputated the employee's right ring fingertip.

Source

Authoritative
OSHA Severe Injury Reports
Machine