← OSHA severe injury reports

Fractures and dislocations

1 hospitalization · 2017065603 · 6/19/2017 · Custom Components & Logistics

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Fractures and dislocations

Cause

Event
Caught in running equipment or machinery, n.e.c.
Source
Brake presses

Employer

Name
Custom Components & Logistics
Location
19722 E. Admiral Pl., CATOOSA, OKLAHOMA, 74015
NAICS
334513
Jurisdiction
1

Narrative

An employee was setting up a press brake and changing from a short die to a long die. While he was holding the lower die partway into position, the press brake was activated via the foot pedal. The lower die then slid fully into position, taking his hand with it. The press brake moved to the setup position and crushed his left hand, breaking his middle finger and dislocating his index finger. He was hospitalized and had surgery.

Source

Authoritative
OSHA Severe Injury Reports
Machine