← OSHA severe injury reports
Heat (thermal) burns, unspecified
1 hospitalization · 2017076263 · 7/7/2017 · Fluidra USA, LLC
Severity
Hospitalized 1
Amputation 0
Loss of eye 0
Body part Leg(s), unspecified
Nature of injury Heat (thermal) burns, unspecified
Cause
Event Explosion of pressure vessel, piping, or tire
Source Pumps
Employer
Name Fluidra USA, LLC
Location 8525 Mallory Road, JACKSONVILLE, FLORIDA, 32220
NAICS 333318
Jurisdiction 1
Narrative An employee had tested a water filter when the water pump overheated and blew up the hose. He suffered burns to the back of his left leg and was hospitalized.