← OSHA severe injury reports

Amputations

1 amputation · 2017076595 · 7/17/2017 · Elixir Door and Metals Co., Inc

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Brake presses

Employer

Name
Elixir Door and Metals Co., Inc
Location
243 Washington Avenue, FITZGERALD, GEORGIA, 31750
NAICS
332321
Jurisdiction
1

Narrative

An employee was operating a press brake to bend a piece of steel. After bending the piece of steel, he re-actuated the press brake with the foot pedal while grabbing the part out of the die. The part broke up toward the front/top of the press (ram) and a previously bent flange caught and amputated his left index and ring fingertips above the knuckle.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown