← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2017099283 · 9/27/2017 · Dryvit Systems, Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Sawing machinery-stationary, n.e.c.

Employer

Name
Dryvit Systems, Inc.
Location
200 First Avenue, CRANSTON, RHODE ISLAND, 02910
NAICS
325998
Jurisdiction
1

Narrative

An employee was loading sticks of material into a multi-saw when a stick became jammed as it was being fed it into the saw blade area. She opened a side door hatch to access the feed compartment and used her fingers to try and adjust the jammed stick. The machine s pneumatic feeding system pushed air into the material feed compartment, which then pushed the stick and the employee s left index finger into the rotating saw blades. Her left index finger was amputated just below the first knuckle.

Source

Authoritative
OSHA Severe Injury Reports
Machine