Amputations

1 amputation · 20171010116 · 10/21/2017 · Lozier Corporation

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Fingernail(s), nailbed(s)
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Welding machinery

Employer

Name
Lozier Corporation
Location
6316 John J. Pershing Drive, OMAHA, NEBRASKA, 68110
NAICS
337215
Jurisdiction
1

Narrative

An employee was attempting to clean the index sensor on a bracket welder because of a machine fault. This did not clear the fault, so the employee attempted to clean the fixture. When the employee cleaned the fixture, the fault cleared and the machine actuated. This caused the magnet to come down on the employee's left index finger, amputating the finger at the second digit.