← OSHA severe injury reports
Fractures
1 hospitalization · 20171010292 · 10/26/2017 · Quality Distribution Inc.
Severity
Hospitalized 1
Amputation 0
Loss of eye 0
Body part Leg(s), unspecified
Nature of injury Fractures
Cause
Event Fall through surface or existing opening, unspecified
Source Existing floor opening
Employer
Name Quality Distribution Inc.
Location 3470 S. Hwy 80, LULING, TEXAS, 78648
NAICS 484121
Jurisdiction 1
Narrative An employee was standing on top of a rig taking pictures of the trailer when the employee stepped backward and fell into a gap between two grid plates, breaking the left leg.
Source
Authoritative OSHA Severe Injury Reports
Machine JSON-LD · Markdown
OSHA severe injury data · MORVS CC0 1.0