← OSHA severe injury reports

Fractures

1 hospitalization · 20171111038 · 11/16/2017 · Specialty Fabricators Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Wrist(s)
Nature of injury
Fractures

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Drills-stationary
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
Specialty Fabricators Inc.
Location
10 Marianne Drive Suite 102, YORK, PENNSYLVANIA, 17406
NAICS
332322
Jurisdiction
1

Narrative

An employee was using a drill press. The drill bit had a burr on it and caught his glove, twisting and fracturing his right wrist into the drill press.

Source

Authoritative
OSHA Severe Injury Reports
Machine