← OSHA severe injury reports

Amputations

1 amputation · 20171212068 · 12/20/2017 · IWM International, LLC

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Grinders, abraders
Secondary source
Screwdrivers-nonpowered

Employer

Name
IWM International, LLC
Location
500 East Middle Street, HANOVER, PENNSYLVANIA, 17331
NAICS
332618
Jurisdiction
1

Narrative

An employee was using a pedestal grinder to grind the tip of a screwdriver when the tool was pulled between the grinding wheel and tool rest. His fingers were pulled in with the screwdriver, partially amputating his left pinky finger to the first knuckle.

Source

Authoritative
OSHA Severe Injury Reports
Machine