← OSHA severe injury reports

Amputations

1 amputation · 2018010033 · 1/2/2018 · Ex-Tech Plastics, Inc.

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, n.e.c.
Source
Extruding machinery

Employer

Name
Ex-Tech Plastics, Inc.
Location
11413 BURLINGTON RD., RICHMOND, ILLINOIS, 60071
NAICS
326199
Jurisdiction
1

Narrative

An employee was setting up an extrusion machine when the employee's right index finger entered a pinch point and was partially amputated.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown