← OSHA severe injury reports

Amputations

1 amputation · 2018065485 · 6/5/2018 · Z J Falcon, LTD

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Oil drilling rigs and machinery

Employer

Name
Z J Falcon, LTD
Location
Stewart Energy, PLAINS, TEXAS, 79355
NAICS
213112
Jurisdiction
1

Narrative

An employee was securing a set of chains to the slip for the blowout preventer (BOP) when the tongs engaged causing the slip to grab pipe and begin to spin. The injured employee's right hand was caught between the slip and BOP, amputating the index fingertip.

Source

Authoritative
OSHA Severe Injury Reports
Machine