← OSHA severe injury reports

Second degree heat (thermal) burns

1 hospitalization · 2018077389 · 7/21/2018 · ERP Compliant COKE, LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Multiple body parts, n.e.c.
Nature of injury
Second degree heat (thermal) burns

Cause

Event
Fire or explosion, unspecified
Source
Nonclassifiable

Employer

Name
ERP Compliant COKE, LLC
Location
3500 35th Ave N, BIRMINGHAM, ALABAMA, 35207
NAICS
324199
Jurisdiction
1

Narrative

Two maintenance employees were working on a compressor inside an exhauster building, tightening screws on the valves/pistons. The outside cover was removed on this unit to gain access to the set screws. One employee left the area and the other employee continued to work when a flash explosion occurred. The employee suffered first and second degree burns to the face and arms.

Source

Authoritative
OSHA Severe Injury Reports
Machine