← OSHA severe injury reports

Electrical burns, unspecified

1 hospitalization · 2018077421 · 7/23/2018 · Select Energy Services, LLC

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Upper and lower limb(s)
Nature of injury
Electrical burns, unspecified

Cause

Event
Indirect exposure to electricity, greater than 220 volts
Source
Forklift, order picker, platform truck-powered
Secondary source
Power lines, transformers, convertors

Employer

Name
Select Energy Services, LLC
Location
Near intersection, WATFORD CITY, NORTH DAKOTA, 58854
NAICS
213112
Jurisdiction
1

Narrative

An employee was acting as a ground guide for a rough-terrain forklift that was loading material onto a flatbed truck. The forklift's boom came into contact with overhead power lines while the employee was touching the forklift. The employee suffered electrical burns to his hands and feet.

Source

Authoritative
OSHA Severe Injury Reports
Machine