← OSHA severe injury reports

Heat (thermal) burns, unspecified

2 hospitalizations · 2018088064 · 8/7/2018 · Surface Dynamics, Inc.

Severity

Hospitalized
2
Amputation
0
Loss of eye
0
Body part
Nonclassifiable
Nature of injury
Heat (thermal) burns, unspecified

Cause

Event
Explosion of pressure vessel, piping, or tire
Source
Special process machinery, n.e.c.
Secondary source
Environmental and elemental conditions, n.e.c.

Employer

Name
Surface Dynamics, Inc.
Location
231 Northland Blvd., CINCINNATI, OHIO, 45246
NAICS
326150
Jurisdiction
1

Narrative

Employees were running a machine (controlled atmosphere plasma spray). The process involves titanium powder. They noticed some sparking on the piping that goes to the dust collector and they started wiping the residue off the piping. A cap on a second set of piping was removed to clean the piping which introduced air into the piping and a flashback occurred. Both employees were hospitalized for burns.