← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 20181010180 · 10/2/2018 · Tecumseh Products

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery, unspecified
Source
Presses, except printing, n.e.c.

Employer

Name
Tecumseh Products
Location
5424 Hwy. 145 South, VERONA, MISSISSIPPI, 38879
NAICS
336312
Jurisdiction
1

Narrative

An employee was adjusting a pin press when it cycled, causing the amputation of the employee's right index fingertip. The press was not locked out at the time.