← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 20181111283 · 11/1/2018 · BALDWIN FILTERS MFG.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Special process machinery, n.e.c.
Secondary source
Belts, gloves, neckties, scarves

Employer

Name
BALDWIN FILTERS MFG.
Location
4400 E HWY 30, KEARNEY, NEBRASKA, 68847
NAICS
336399
Jurisdiction
1

Narrative

An employee had been watching the gears on the back side of a pleater, trying to determine what was causing a pleater to "jump" and not work properly. The cuff of her left glove was caught in the gears; as she tried to free it, the gears grabbed the tip of her right glove, pulling in her right index finger and causing an amputation to the finger. The machine was not guarded at the time.

Source

Authoritative
OSHA Severe Injury Reports
Machine
JSON-LD · Markdown