Third or fourth degree electrical burns

1 hospitalization · 20181112195 · 11/28/2018 · GENERAL DYNAMICS NASSCO

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Nonclassifiable
Nature of injury
Third or fourth degree electrical burns

Cause

Event
Direct exposure to electricity, unspecified
Source
Switchboards, switches, fuses

Employer

Name
GENERAL DYNAMICS NASSCO
Location
m/v USS Miguel Keith, SAN DIEGO, CALIFORNIA, 92113
NAICS
336611
Jurisdiction
0

Narrative

An employee was performing continuity testing on a circuit breaker. An alligator clip touched energized parts of the circuit breaker, causing an arc flash. The employee suffered second- and third-degree burns.