← OSHA severe injury reports

Amputations

1 amputation · 2019055358 · 5/29/2019 · Northern States Power Company

Severity

Hospitalized
0
Amputation
1
Loss of eye
0
Body part
Fingertip(s)
Nature of injury
Amputations

Cause

Event
Struck against stationary object or equipment, n.e.c.
Source
Fans, blowers-wall, floor, ceiling, ventilation
Secondary source
Nails, brads, tacks, nuts, bolts, washers

Employer

Name
Northern States Power Company
Location
Ladysmith Hydro, LADYSMITH, WISCONSIN, 54848
NAICS
221111
Jurisdiction
1

Narrative

On May 29, 2019, at 1:30 p.m., an electrical maintenance technician was using a wrench to tighten a bolt on a roof exhaust fan assembly. As the employee was tightening the bolt, it broke causing their right hand to strike against the fan assembly resulting in amputation of the ring and index fingertips. The fan's energy source was isolated and locked out at the time.