← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2019055418 · 5/30/2019 · Marine Acquisition Corporation US

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Amputations

Cause

Event
Caught in running equipment or machinery during regular operation
Source
Product testing, inspecting, and diagnostic machinery, n.e.c.

Employer

Name
Marine Acquisition Corporation US
Location
640 N. Lewis Road, LIMERICK, PENNSYLVANIA, 19468
NAICS
335314
Jurisdiction
1

Narrative

An employee was operating a conduit-fitting pull test machine when he noticed the cable was not fully seated in the jaws. He pushed down the cable into the jaws. When the cable clicked into position, the machine finished the cycle with his fingertip still inside it, resulting in an amputation. The machine was guarded and had a light curtain on at the time of the incident.

Source

Authoritative
OSHA Severe Injury Reports
Machine