← OSHA severe injury reports

Electrocutions, electric shocks

1 hospitalization · 2019065626 · 6/4/2019 · Northlake Shipyard, Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
BODY SYSTEMS
Nature of injury
Electrocutions, electric shocks

Cause

Event
Machinery or equipment incident on water vehicle
Source
Commercial fishing vessel
Secondary source
Power cords, electrical cords, extension cords

Employer

Name
Northlake Shipyard, Inc.
Location
FV Alaska Mist, SEATTLE, WASHINGTON, 98103
NAICS
336611
Jurisdiction
0

Narrative

Before noon on June 4, 2019, a marine inspector was conducting an inspection on board a fishing vessel at a shipyard. As the employee was climbing out of the vessel's anchor chain locker, he was shocked by a damaged extension cord running through a chain attached to shelving on a bulkhead. He suffered nerve damage to his thumb and thermal burns to his forearm muscle, and was hospitalized.

Source