← OSHA severe injury reports

Amputations

1 amputation, 1 hospitalization · 2019088285 · 8/12/2019 · MasTec Services Company, Inc.

Severity

Hospitalized
1
Amputation
1
Loss of eye
0
Body part
Finger(s), fingernail(s), n.e.c.
Nature of injury
Amputations

Cause

Event
Compressed or pinched by shifting objects or equipment
Source
Gears
Secondary source
Drills-powered

Employer

Name
MasTec Services Company, Inc.
Location
ROW near intersection of 458th Ave., PEEVER, SOUTH DAKOTA, 57257
NAICS
238210
Jurisdiction
1

Narrative

An employee was attempting to remove a drive gear from beneath equipment. The employee was operating a pneumatic drill with his left hand while bracing himself with his right hand on the drive gear. The torque of the drill caused the gear to shift and catch the distal phalange of his right pinky finger, resulting in a partial amputation.

Source

Authoritative
OSHA Severe Injury Reports
Machine