← OSHA severe injury reports

Avulsions, enucleations

1 hospitalization · 20191010745 · 10/14/2019 · Cleveland Specialty Products Inc.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Finger(s), fingernail(s), unspecified
Nature of injury
Avulsions, enucleations

Cause

Event
Caught in running equipment or machinery during maintenance, cleaning
Source
Metal, woodworking, and special material machinery, unspecified

Employer

Name
Cleveland Specialty Products Inc.
Location
2130 West 110th Street, CLEVELAND, OHIO, 44102
NAICS
326199
Jurisdiction
1

Narrative

An employee was cleaning plastic film that had dripped from the hanger die of a bubble machine. The employee's left hand was caught between the machine's roller and nip roller, causing fractured fingers and a degloving injury to the ring and index fingers.

Source

Authoritative
OSHA Severe Injury Reports
Machine