← OSHA severe injury reports

Soreness, pain, hurt-nonspecified injury

1 hospitalization · 2020021323 · 2/10/2020 · Bass Energy Services, LLC.

Severity

Hospitalized
1
Amputation
0
Loss of eye
0
Body part
Multiple trunk locations
Nature of injury
Soreness, pain, hurt-nonspecified injury

Cause

Event
Struck by dislodged flying object, particle
Source
Valves, nozzles
Secondary source
Pressurized air-blast

Employer

Name
Bass Energy Services, LLC.
Location
1197 Magnolia rd, WASKOM, TEXAS, 75692
NAICS
213112
Jurisdiction
1

Narrative

An employee was on a 5-foot ladder repairing a hydraulic valve and changing the internal packing. He used pressurized air to push the piston up. He then bled the fluid out of the valve. Once he removed the last bolt, pressure released, and the valve housing struck the employee in the rib area knocking him off the ladder. The employee sustained bruised ribs and back pain.

Source

Authoritative
OSHA Severe Injury Reports
Machine